Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Dent J (Basel) ; 12(3)2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38534267

RESUMO

Reconstruction of sufficient buccal peri-implant keratinised mucosa width (PIKM-W) is reported to reduce the symptoms of peri-implantitis. In order to reduce the drawbacks of autogenous graft harvesting, we investigated a novel porcine dermal matrix (XDM, mucoderm®) using a modified surgical technique for augmentation of PIKM-W. Twenty-four patients were recruited with insufficient (<2 mm) PIKM-W. After split thickness flap preparation, the XDM was trimmed, rehydrated and tightly attached to the recipient periosteal bed using modified internal/external horizontal periosteal mattress sutures via secondary wound healing. Change of the PIKM-W and dimension of the graft remodelling were evaluated at 6 and 12 months postoperatively. The mean PIKM-W changed from 0.42 ± 0.47 to 3.17 ± 1.21 mm at 6 M and to 2.36 ± 1.34 mm at 12 M in the maxilla and from 0.29 ± 0.45 mm to 1.58 ± 1.44 mm at 6 M and to 1.08 ± 1.07 mm at 12 M in the mandible. Graft dimensions decreased by 67.7 ± 11.8% and 81.6 ± 16.6% at 6 M, and continued to 75.9 ± 13.9% and 87.4 ± 12.3% at 12 M, in the maxilla and mandible, respectively. Clinical parameters showed statistically significant intra- and intergroup differences between the baseline and 6 and 12 months (p < 0.05). The present technique using the XDM was safe and successfully reconstructed PIKM-W in both arches. The XDM alone seems to be a suitable alternative to autograft for PIKM-W augmentation in the maxilla.

2.
Quintessence Int ; 55(4): 314-326, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38502155

RESUMO

OBJECTIVES: This case series aimed to assess the efficacy of a novel horizontal ridge augmentation modality using histology. Combinations of "sticky bone" and tenting screws without autologous bone were used as augmentative materials. METHOD AND MATERIALS: Five individuals presenting healed, atrophic, partially edentulous sites that required horizontal bone augmentation before implant placement were enrolled. Patients underwent the same augmentation type and 5 months of postoperative reentry procedures. The first surgery served as implant site development, whereas the biopsy and corresponding implant placement were performed during reentry. The bone was qualitatively analyzed using histology and histomorphometry and quantitatively evaluated using CBCT. RESULTS: Four individuals healed uneventfully. Early wound dehiscence occurred in one case. Histology showed favorable bone substitute incorporation into the newly formed bone and intimate contact between de novo bone and graft material in most cases. Histomorphometry revealed an average of 48 ± 28% newly formed bone, 19 ± 13% graft material, and 33 ± 26% soft tissue components. The CBCT-based mean alveolar ridge horizontal increase was 3.9 ± 0.6 mm at 5 months postoperatively. CONCLUSIONS: The described augmentation method appears suitable for implant site development resulting in favorable bone quality according to histology. However, clinicians must accommodate 1 to 2 mm of resorption in augmentative material width at the buccal aspect.


Assuntos
Aumento do Rebordo Alveolar , Substitutos Ósseos , Tomografia Computadorizada de Feixe Cônico , Humanos , Aumento do Rebordo Alveolar/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Substitutos Ósseos/uso terapêutico , Implantação Dentária Endóssea/métodos , Resultado do Tratamento , Arcada Parcialmente Edêntula , Adulto , Biópsia , Idoso , Parafusos Ósseos
3.
Medicina (Kaunas) ; 59(10)2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37893416

RESUMO

Background and Objectives: A rigid, resorbable magnesium membrane was recently developed, combining the advantages of resorbable and non-resorbable membranes. Our aim was to describe the application of this membrane for guided bone regeneration (GBR). Materials and Methods: This case report described the treatment and 3D evaluation of two cases utilizing a resorbable magnesium barrier membrane. In Case #1, GBR was performed with a bilayer tunnel flap. The magnesium barrier was placed fixed subperiosteally through remote vertical incisions. In Case #2, GBR was performed using a split-thickness flap design. Volumetric and linear hard tissue alterations were assessed by 3D cone-beam computed tomography subtraction analysis, as well as with conventional intraoral radiography. Results: Case #1 showed a volumetric hard tissue gain of 0.12 cm3, whereas Case #2 presented a 0.36 cm3 hard tissue gain. No marginal peri-implant hard tissue loss could be detected at the two-year follow-up. Conclusions: The application of conventional resorbable collagen membranes would be difficult in either of the cases presented. However, the rigid structure of the magnesium membrane allowed for the limitations of conventional resorbable membranes to be overcome.


Assuntos
Aumento do Rebordo Alveolar , Magnésio , Humanos , Seguimentos , Magnésio/uso terapêutico , Estudos Retrospectivos , Aumento do Rebordo Alveolar/métodos , Membranas Artificiais
4.
Int J Periodontics Restorative Dent ; 0(0): 1-18, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37722007

RESUMO

Guided bone regeneration (GBR) requires a tension-free flap without damaging the collateral circulation in order to secure better surgical outcomes. Topographical acknowledgment of the muscular and neurovascular structures in the territory of the mandible can prevent complications during lingual flap design. The lingual branch (LB) of the inferior alveolar- or maxillary arteries is not well illustrated or described in the literature. Nevertheless, it has an intimate relationship to the lingual nerve (LN) during ridge augmentation and implant-related surgeries of the posterior mandible. Therefore, this study aimed to clarify the morphology and topography of the LB related to GBR surgeries. In the present human cadaveric study, the LB was analyzed in twelve hemimandibles using latex injection and corrosion casting. We identified two types of LB based on its origin and course. For both types, LB was found in a common connective tissue sheath close to the LN's origin and supplied the nerve. Several anastomoses between the LB and other arteries on the posterior lingual aspect of the mandible were observed. The LB acted as an anatomical landmark in identifying LN at the posterior lingual aspect of the mandible.

5.
Clin Oral Investig ; 27(7): 3927-3935, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37055540

RESUMO

OBJECTIVES: The aim of this retrospective case series was to evaluate the efficacy and volume stability of a customized allogeneic bone block (CABB) for the hard tissue reconstruction of severely atrophied anterior maxillary ridges. MATERIALS AND METHODS: Hard tissue alterations between baseline (T1), 2-month follow-up (T2), and 6-month follow-up (T3) cone-beam computed tomography scans were evaluated with semi-automatic segmentation. Following automatic spatial alignment of the datasets, 3D subtraction analysis was performed. The volume stability of the inserted allogeneic bone block was determined on the basis of the ratio of the T3 and T2 hard tissue volumes. RESULTS: The newly formed hard tissue volume at T2 averaged at of 0.75 cm3 ± 0.57 cm3, whereas at T3, an average of 0.52 cm3 ± 0.42 cm3 volumetric hard tissue gain could be detected. The T3/T2 ratio was found to be 67.83% ± 18.72% on average. The dice similarity coefficient between the T2 and T3 hard tissue models averaged at 0.73 ± 0.15. CONCLUSIONS: Cancellous CABBs are a reliable option for the reconstruction of severely atrophied alveolar ridges. The resorption rates of these grafts are similar to those found in the literature; however, with precise manufacturing and proper intraoperative flap management, the resorption rates may be reduced. CLINICAL RELEVANCE: With precise knowledge of the resorption patterns, the shape of blocks can be altered in the future to compensate for the volumetric loss.


Assuntos
Aumento do Rebordo Alveolar , Transplante de Células-Tronco Hematopoéticas , Transplante Ósseo/métodos , Estudos Retrospectivos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Processo Alveolar/diagnóstico por imagem , Processo Alveolar/cirurgia , Aumento do Rebordo Alveolar/métodos , Implantação Dentária Endóssea
6.
Quintessence Int ; 54(5): 358-370, 2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-36723496

RESUMO

OBJECTIVES: The aim of this report was to present the effectiveness of a novel augmented corticotomy performed before orthodontic treatments in the prevention of buccal alveolar dehiscence and gingival recession. METHOD AND MATERIALS: Four periodontally healthy individuals presenting crowding and thin bone morphotype in the mandibular anterior area were treated with a double-layer tunnel flap, piezotomy, and hard and soft-tissue augmentation. Patients were divided into two groups according to the utilized graft material. The exclusive use of demineralized bovine bone minerals (group 2) was compared to the use of autologous concentrated growth factor-enriched bone graft matrix, "sticky bone" (group 1). CBCT measurements were performed before and 6 months after surgery. Orthodontic treatment was initialized 1 week after surgery. RESULTS: Postoperative wound healing was uneventful, and tooth alignments were successful in all cases. Postoperative buccal hard tissue dimensions were favorable in both groups, with no occurring bone dehiscence or gingival recession. The seemingly better results of group 2, in terms of quantitative hard tissue changes, did not have any clinical significance according to the objective to be achieved. In contrast, qualitative radiographic analysis showed a more homogenous tissue formation around teeth in group 1. CONCLUSION: It can be concluded that the presented preorthodontic treatment approach seems to be successful in preventing alveolar dehiscence and gingival recession around buccally inclined mandibular anterior teeth.


Assuntos
Retração Gengival , Ortodontia , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Animais , Bovinos , Retração Gengival/diagnóstico por imagem , Retração Gengival/cirurgia , Osteogênese
7.
BMC Oral Health ; 23(1): 118, 2023 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-36810076

RESUMO

OBJECTIVES: To analyze morphological, volumetric, and linear hard tissue changes following horizontal ridge augmentation using a three-dimensional radiographic method. METHODS: As part of a larger ongoing prospective study, 10 lower lateral surgical sites were selected for evaluation. Horizontal ridge deficiencies were treated with guided bone regeneration (GBR) using a split-thickness flap design and a resorbable collagen barrier membrane. Following the segmentation of baseline and 6-month follow-up cone-beam computed tomography scans, volumetric, linear, and morphological hard tissue changes and the efficacy of the augmentation were assessed (expressed by the volume-to-surface ratio). RESULTS: Volumetric hard tissue gain averaged 605.32 ± 380.68 mm3. An average of 238.48 ± 127.82 mm3 hard tissue loss was also detected at the lingual aspect of the surgical area. Horizontal hard tissue gain averaged 3.00 ± 1.45 mm. Midcrestal vertical hard tissue loss averaged 1.18 ± 0.81 mm. The volume-to-surface ratio averaged 1.19 ± 0.52 mm3/mm2. The three-dimensional analysis showed slight lingual or crestal hard tissue resorption in all cases. In certain instances, the greatest extent of hard tissue gain was observed 2-3 mm apical to the initial level of the marginal crest. CONCLUSIONS: With the applied method, previously unreported aspects of hard tissue changes following horizontal GBR could be examined. Midcrestal bone resorption was demonstrated, most likely caused by increased osteoclast activity following the elevation of the periosteum. The volume-to-surface ratio expressed the efficacy of the procedure independent of the size of the surgical area.


Assuntos
Perda do Osso Alveolar , Aumento do Rebordo Alveolar , Regeneração Óssea , Humanos , Aumento do Rebordo Alveolar/métodos , Transplante Ósseo/métodos , Implantação Dentária Endóssea/métodos , Estudos Prospectivos , Retalhos Cirúrgicos
8.
BMC Oral Health ; 22(1): 490, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36376891

RESUMO

OBJECTIVES: The aim of this study was to evaluate the effects of membrane exposure during vertical ridge augmentation (VRA) utilizing guided bone regeneration with a dense polytetrafluoroethylene (d-PTFE) membrane and a tent-pole space maintaining approach by registering radiographic volumetric, linear and morphological changes. METHODS: In 8 cases alveolar ridge defects were accessed utilizing a split-thickness flap design. Following flap elevation VRA was performed with tent-pole space maintaining approach utilizing the combination of a non-reinforced d-PTFE membrane and a composite graft (1:1 ratio of autogenous bone chips and bovine derived xenografts). Three-dimensional radiographic evaluation of hard tissue changes was carried out with the sequence of cone-beam computed tomography (CBCT) image segmentation, spatial registration and 3D subtraction analysis. RESULTS: Class I or class II membrane exposure was observed in four cases. Average hard tissue gain was found to be 0.70 cm3 ± 0.31 cm3 and 0.82 cm3 ± 0.40 cm3 with and without membrane exposure resulting in a 17% difference. Vertical hard tissue gain averaged 4.06 mm ± 0.56 mm and 3.55 mm ± 0.43 mm in case of submerged and open healing, respectively. Difference in this regard was 14% between the two groups. Horizontal ridge width at 9-month follow-up was 5.89 mm ± 0.51 mm and 5.61 mm ± 1.21 mm with and without a membrane exposure respectively, resulting in a 5% difference. CONCLUSIONS: With the help of the currently reported 3D radiographic evaluation method, it can be concluded that exposure of the new-generation d-PTFE membrane had less negative impact on clinical results compared to literature data reporting on expanded polytetrafluoroethylene membranes.


Assuntos
Perda do Osso Alveolar , Aumento do Rebordo Alveolar , Humanos , Bovinos , Animais , Aumento do Rebordo Alveolar/métodos , Politetrafluoretileno/uso terapêutico , Regeneração Tecidual Guiada Periodontal/métodos , Membranas Artificiais , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/cirurgia , Perda do Osso Alveolar/tratamento farmacológico , Processo Alveolar/cirurgia , Transplante Ósseo/métodos , Implantação Dentária Endóssea/métodos
9.
Materials (Basel) ; 15(12)2022 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-35744169

RESUMO

Nowadays, the most commonly used fixation systems are non-resorbable, but new resorbable magnesium alloy fixation screws have been introduced recently. Therefore, the aim of this study was to compare the magnesium fixation screw and the commonly used non-resorbable titanium screw in an animal model. Four 3-wall defect sites were covered with collagen membranes in the mandible of twenty beagle dogs (two sites on the left and two on the right). Each membrane was fixed with either four magnesium screws or four titanium screws. Post-operative follow-up revealed the expected observations such as transient inflammation and pain. Both groups showed a good healing response, with no differences between groups. Micro-CT analysis showed no significant difference between groups in terms of BV/TV or soft tissue volume. The void volume in the magnesium fixation screw group continued to decrease on average between the different timepoints, but not significantly. Furthermore, a gradual progression of the degradation process of the magnesium screws was observed in the same group. Magnesium screws and titanium screws showed equal performance in tissue regeneration according to GBR principles. An additional advantage of magnesium screws is their resorbable nature, which eliminates the need for a second surgical step to remove the screws.

10.
Int J Implant Dent ; 8(1): 23, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35532820

RESUMO

PURPOSE: Placement of dental implants has evolved to be an advantageous treatment option for rehabilitation of the fully or partially edentulous mandible. In case of extensive horizontal bone resorption, the bone volume needs to be augmented prior to or during implant placement in order to obtain dental rehabilitation and maximize implant survival and success. METHODS: Our aim was to systematically review the available data on lateral augmentation techniques in the horizontally compromised mandible considering all grafting protocols using xenogeneic, synthetic, or allogeneic material. A computerized and manual literature search was performed for clinical studies (published January 1995 to March 2021). RESULTS: Eight studies ultimately met the inclusion criteria comprising a total of 276 procedures of xenogeneic, allogeneic, or autogenous bone graft applications in horizontal ridge defects. Particulate materials as well as bone blocks were used as grafts with a mean follow-up of 26.0 months across all included studies. Outcome measures, approaches and materials varied from study to study. A gain of horizontal bone width of the mandible with a mean of 4.8 mm was observed in seven of eight studies. All but one study, reported low bone graft failure rates of 4.4% in average. CONCLUSIONS: Only limited data are available on the impact of different horizontal augmentation strategies in the mandible. The results show outcomes for xenogeneic as well as autologous bone materials for horizontal ridge augmentation of the lower jaw. The use of allogeneic bone-block grafts in combination with resorbable barrier membranes must be re-evaluated. Randomized controlled clinical trials are largely missing.


Assuntos
Aumento do Rebordo Alveolar , Reabsorção Óssea , Aumento do Rebordo Alveolar/métodos , Transplante Ósseo/métodos , Implantação Dentária Endóssea/métodos , Humanos , Mandíbula/cirurgia
11.
Materials (Basel) ; 15(9)2022 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-35591440

RESUMO

For the surgical technique of guided bone regeneration (GBR), the choice of available barrier membranes has until recently not included an option that is mechanically strong, durable, synthetic and resorbable. The most commonly used resorbable membranes are made from collagen, which are restricted in their mechanical strength. The purpose of this study is to evaluate the degradation and regeneration potential of a magnesium membrane compared to a collagen membrane. In eighteen beagle dogs, experimental bone defects were filled with bovine xenograft and covered with either a magnesium membrane or collagen membrane. The health status of the animals was regularly monitored and recorded. Following sacrifice, the hemimandibles were prepared for micro-CT (µ-CT) analysis. Complications during healing were observed in both groups, but ultimately, the regenerative outcome was similar between groups. The µ-CT parameters showed comparable results in both groups in terms of new bone formation at all four time points. In addition, the µ-CT analysis showed that the greatest degradation of the magnesium membranes occurred between 1 and 8 weeks and continued until week 16. The proportion of new bone within the defect site was similar for both treatment groups, indicating the potential for the magnesium membrane to be used as a viable alternative to collagen membranes. Overall, the new magnesium membrane is a functional and safe membrane for the treatment of defects according to the principles of GBR.

12.
Clin Oral Investig ; 26(8): 5261-5272, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35593928

RESUMO

OBJECTIVES: The present randomized controlled clinical study aimed to investigate if, in lateral maxillary sinus augmentation, the repositioned bony wall or the application of a collagen membrane results in more preferable new hard tissue formation. MATERIALS AND METHODS: Forty patients were divided into two study groups. Both groups received a xenogeneic bone substitute material (BSM) during lateral sinus augmentation. In the bony wall group (BW), following piezosurgery, the retrieved bony wall was repositioned. In the collagen membrane group (CM), following rotary instrument preparation, collagen membrane coverage was applied. After 6 months, biopsies were taken to histologically analyze the percentage of BSM, connective tissue (CT), and newly formed bone (NFB) following both approaches. RESULTS: Forty implants were placed and 29 harvested biopsies could be evaluated. Duration of surgery, membrane perforations, and VAS were detected. Histomorphometrical analysis revealed comparable amounts of all analyzed parameters in both groups in descending order: CT (BW: 39.2 ± 9%, CM: 37,9 ± 8.5%) > BSM (BW: 32.9 ± 6.3%, CM: 31.8 ± 8.8%) > NB (BW: 27.8 ± 11.2%, CM: 30.3 ± 4.5%). CONCLUSIONS: The results of the present study show that the closure of the access window by means of the retrieved bony wall or a native collagen membrane led to comparable bone augmentation results. CLINICAL TRIAL: clinicaltrials.gov NCT04811768. CLINICAL RELEVANCE: Lateral maxillary sinus augmentation with the application of a xenogeneic BSM in combination with a native collagen membrane for bony window coverage represents a reliable method for surgical reconstruction of the posterior maxilla. Piezosurgery with bony window repositioning delivers comparable outcomes without membrane coverage.


Assuntos
Substitutos Ósseos , Levantamento do Assoalho do Seio Maxilar , Seios Transversos , Regeneração Óssea , Colágeno , Implantação Dentária Endóssea/métodos , Humanos , Maxila/patologia , Maxila/cirurgia , Seio Maxilar/patologia , Seio Maxilar/cirurgia , Estudos Prospectivos , Levantamento do Assoalho do Seio Maxilar/métodos , Seios Transversos/cirurgia
13.
Quintessence Int ; 53(6): 492-501, 2022 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-35274512

RESUMO

OBJECTIVE: The aim of the current article was to present a radiographic method to determine the surface area of newly formed periodontal attachment, as well as to analyze volumetric and morphologic changes after regenerative periodontal treatment. METHOD AND MATERIALS: In this retrospective study, 11 singular intrabony periodontal defects were selected for minimally invasive surgical treatment and 3D evaluation. 3D virtual models were acquired by the segmentation of pre- and postoperative CBCT scans. This study determined the surface area of baseline periodontal attachment (RSA-A) and defect-involved root surface (RSA-D) on the preoperative 3D models, and the surface area of new periodontal attachment (RSA-NA) on the postoperative models. Finally, cumulative change of periodontal attachment (∆RSA-A) was calculated and Boolean subtraction was applied on pre- and postoperative 3D models to demonstrate postoperative 3D hard tissue alterations. RESULTS: The average RSA-A was 84.39 ± 33.27 mm2, while the average RSA-D was 24.26 ± 11.94 mm2. The average surface area of RSA-NA after regenerative periodontal surgery was 17.68 ± 10.56 mm2. Additionally, ∆RSA-A was determined to assess the overall effects of ridge alterations on periodontal attachment, averaging 15.53 ± 12.47 mm2, which was found to be statistically significant (P = .00149). Lastly, the volumetric hard tissue gain was found to be 33.56 ± 19.35 mm3, whereas hard tissue resorption of 26.31 ± 38.39 mm3 occurred. CONCLUSION: The proposed 3D radiographic method provides a detailed understanding of new periodontal attachment formation and hard tissue alterations following regenerative surgical treatment of intrabony periodontal defects.


Assuntos
Perda do Osso Alveolar , Doenças Periodontais , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/cirurgia , Seguimentos , Regeneração Tecidual Guiada Periodontal/métodos , Humanos , Perda da Inserção Periodontal/diagnóstico por imagem , Perda da Inserção Periodontal/cirurgia , Doenças Periodontais/cirurgia , Bolsa Periodontal/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
14.
Bioact Mater ; 14: 152-168, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35310351

RESUMO

Barrier membranes are commonly used as part of the dental surgical technique guided bone regeneration (GBR) and are often made of resorbable collagen or non-resorbable materials such as PTFE. While collagen membranes do not provide sufficient mechanical protection of the covered bone defect, titanium reinforced membranes and non-resorbable membranes need to be removed in a second surgery. Thus, biodegradable GBR membranes made of pure magnesium might be an alternative. In this study a biodegradable pure magnesium (99.95%) membrane has been proven to have all of the necessary requirements for an optimal regenerative outcome from both a mechanical and biological perspective. After implantation, the magnesium membrane separates the regenerating bone from the overlying, faster proliferating soft tissue. During the initial healing period, the membrane maintained a barrier function and space provision, whilst retaining the positioning of the bone graft material within the defect space. As the magnesium metal corroded, it formed a salty corrosion layer and local gas cavities, both of which extended the functional lifespan of the membrane barrier capabilities. During the resorption of the magnesium metal and magnesium salts, it was observed that the membrane became surrounded and then replaced by new bone. After the membrane had completely resorbed, only healthy tissue remained. The in vivo performance study demonstrated that the magnesium membrane has a comparable healing response and tissue regeneration to that of a resorbable collagen membrane. Overall, the magnesium membrane demonstrated all of the ideal qualities for a barrier membrane used in GBR treatment.

15.
Bioact Mater ; 14: 15-30, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35310352

RESUMO

An ideal fixation system for guided bone (GBR) regeneration in oral surgery must fulfil several criteria that includes the provision of adequate mechanical fixation, complete resorption when no longer needed, complete replacement by bone, as well as be biocompatible and have a good clinical manageability. For the first time, a biodegradable magnesium fixation screw made of the magnesium alloy WZM211 with a MgF2 coating has been designed and tested to fulfill these criteria. Adequate mechanical fixation was shown for the magnesium fixation screw in several benchtop tests that directly compared the magnesium fixation screw with an equivalent polymeric resorbable device. Results demonstrated slightly superior mechanical properties of the magnesium device in comparison to the polymeric device even after 4 weeks of degradation. Biocompatibility of the magnesium fixation screw was demonstrated in several in vitro and in vivo tests. Degradation of the magnesium screw was investigated in in vitro and in vivo tests, where it was found that the screw is resorbed slowly and completely after 52 weeks, providing adequate fixation in the early critical healing phase. Overall, the magnesium fixation screw demonstrates all of the key properties required for an ideal fixation screw of membranes used in guided bone regeneration (GBR) surgeries.

16.
Clin Oral Investig ; 26(1): 1035-1043, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34401946

RESUMO

OBJECTIVES: To compare the accuracy of implant placement performed with either a surgical motor or a torque wrench as part of a half-guided surgical protocol. MATERIALS AND METHODS: Implant insertion with half-guided surgical protocol was utilized by surgical motor (machine-driven group) or torque wrench (manual group) in the posterior maxilla. After the healing period, accuracy comparison between planned and actual implant positions was performed based on preoperative cone beam computed tomography and postoperative digital intraoral scans. Coronal, apical, and angular deviations, insertion time, and insertion torque were evaluated. RESULTS: Forty patients were treated with 1 implant each; 20 implants were inserted with a surgical motor and 20 implants with a torque wrench. Global coronal and apical deviations were 1.20 ± 0.46 mm and 1.45 ± 0.79 mm in the machine-driven group, and 1.13 ± 0.38 mm and 1.18 ± 0.28 mm in the manual group (respectively). The mean angular deviation was 4.82 ± 2.07° in the machine-driven group and 4.11 ± 1.63° in the manual group. Mean insertion torque was 21.75 ± 9.75 Ncm in the machine-driven group, compared to 18.75 ± 7.05 Ncm in the manual group. Implant placement duration was 9.25 ± 1.86 s in the machine-driven group at a speed of 50 rpm, and 36.40 ± 8.15 s in the manual group. CONCLUSION: No significant difference was found between the two groups in terms of accuracy and mean insertion torque, while machine-driven implant placement was significantly less time-consuming. CLINICAL RELEVANCE: Optimal implant placement accuracy utilized by half-guided surgical protocol can be achieved with both machine-driven and torque wrench insertion. TRIAL REGISTRATION: ID: NCT04854239.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Humanos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Estudos Prospectivos
17.
Clin Oral Investig ; 26(2): 1811-1821, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34491446

RESUMO

OBJECTIVES: Minimally invasive flap designs have been introduced to enhance blood clot stability and support wound healing. Limited data appear to suggest, that in intrabony defects, better clinical outcomes can be achieved by means of minimally invasive flap compared to more extended flaps. The aim of this study was to evaluate the healing of intrabony defects treated with either minimally invasive surgical flaps or with modified or simplified papilla preservation techniques in conjunction with the application of an enamel matrix derivative (EMD). MATERIALS AND METHODS: Forty-seven subjects were randomly assigned to either test (N = 23) or control (N = 24) procedures. In the test group, the intrabony defects were accessed by means of either minimally invasive surgical technique (MIST) or modified minimally invasive surgical technique (M-MIST) according to the defect localization while the defects in the control group were treated with either the modified or simplified papilla preservation (MPP) or the simplified papilla preservation technique (SPP). EMD was used as regenerative material in all defects. The following clinical parameters were recorded at baseline and after 12 months: full-mouth plaque score (FMPS), full-mouth bleeding score (FMBS), probing depths (PD), clinical attachment level (CAL), and gingival recession (GR). Early healing index (EHI) score was assessed in both groups 1 week following the surgery. CAL gain was set as primary outcome. RESULTS: After 12 months follow-up, the CAL gain was 4.09 ± 1.68 mm in test group and 3.79 ± 1.67 mm in control group, while the PD reduction was 4.52 ± 1.34 mm and 4.04 ± 1.62 mm for test and control sites. In both groups, a minimal GR increase (0.35 ± 1.11 mm and 0.25 ± 1.03 mm) was noted. No residual PDs ≥ 6 mm were recorded in both groups. CAL gains of 4-5 mm were achieved in 30.4% and in 29.2% of test and control group, respectively. Moreover, CAL gains ≥ 6 mm were recorded in 21.7% of experimental sites and in 20.8% of control sites. No statistically significant differences in any of the evaluated parameters were found between the test and control procedures (P > 0.05). After 1 week post-surgery, a statistically significant difference (P < 0.05) between the groups was found in terms of EHI score. CONCLUSIONS: Within the limits of this pilot RCT, the results have failed to show any differences in the measured parameters following treatment of intrabony defects with EMD, irrespective of the employed surgical technique. CLINICAL RELEVANCE: In intrabony defects, the application of EMD in conjunction with either MIST/M-MIST or M-PPT/SPPT resulted in substantial clinical improvements.


Assuntos
Perda do Osso Alveolar , Proteínas do Esmalte Dentário , Retração Gengival , Perda do Osso Alveolar/cirurgia , Seguimentos , Retração Gengival/cirurgia , Regeneração Tecidual Guiada Periodontal , Humanos , Perda da Inserção Periodontal , Retalhos Cirúrgicos , Resultado do Tratamento , Cicatrização
18.
Int J Comput Dent ; 24(3): 241-251, 2021 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-34553889

RESUMO

AIM: The purpose of this article is to present a novel method for the CBCT subtraction analysis of 3D changes following alveolar ridge preservation (ARP) with the application of a semi-automatic segmentation workflow and spatial registration. The study hypothesis was that by utilizing our novel approach, better 3D visualization and improved volumetric and linear evaluations of alveolar reconstructive procedures could be achieved following ARP compared with existing methodologies. MATERIALS AND METHODS: Ten surgical sites of 10 partially edentulous patients were treated with a tunneled guided bone regeneration approach for ARP. Spatial registration and a semi-automatic segmentation method were utilized to create 3D digital models of pre- and postoperative CBCT datasets for subtraction analysis. The primary outcome variable of the study was the volumetric difference between pre- and postoperative CBCT scans. Secondary outcome variables were horizontal and vertical linear measurements at the mesial, distal, and middle aspects of the alveolus. RESULTS: Change of hard tissue volume averaged at 0.34 ± 0.99 cm3. The mean change of vertical hard tissue dimension was 5.97 ± 3.18 mm at the mesial, 6.40 ± 3.03 mm at the distal, and 7.01 ± 3.02 mm at the middle aspect of the extraction sites. Horizontal linear changes averaged at 6.19 ± 0.68 mm at the mesial, 6.32 ± 1.52 mm at the distal, and 6.90 ± 1.48 mm at the middle aspects of the extraction sites. CONCLUSION: The digital reconstruction of CBCT datasets with the presented approach may provide a better understanding of the healing mechanisms following ARP. Not only the direct effect on extraction socket healing, but also the indirect positive effect on adjacent teeth can be visualized.


Assuntos
Perda do Osso Alveolar , Aumento do Rebordo Alveolar , Tomografia Computadorizada de Feixe Cônico Espiral , Perda do Osso Alveolar/diagnóstico por imagem , Processo Alveolar/diagnóstico por imagem , Processo Alveolar/cirurgia , Seguimentos , Humanos , Extração Dentária , Alvéolo Dental/cirurgia
19.
Clin Case Rep ; 9(9): e04771, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34532047

RESUMO

After initial resorption, the bone volume showed long-term stability following loading of the implant. Furthermore, 3D matching was a suitable quantification method to analyze the volume development of bone augmentation.

20.
J Vis Exp ; (174)2021 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-34424231

RESUMO

Virtual, hybrid three-dimensional (3D) model acquisition is presented in this article, utilizing the sequence of radiographic image segmentation, spatial registration, and free-form surface modeling. Firstly cone-beam computed tomography datasets were reconstructed with a semi-automatic segmentation method. Alveolar bone and teeth are separated into different segments, allowing 3D morphology, and localization of periodontal intrabony defects to be assessed. The severity, extent, and morphology of acute and chronic alveolar ridge defects are validated concerning adjacent teeth. On virtual complex tissue models, positions of dental implants can be planned in 3D. Utilizing spatial registration of IOS and CBCT data and subsequent free-form surface modeling, realistic 3D hybrid models can be acquired, visualizing alveolar bone, teeth, and soft tissues. With the superimposition of IOS and CBCT soft tissue, thickness above the edentulous ridge can be assessed about the underlying bone dimensions; therefore, flap design and surgical flap management can be determined, and occasional complications may be avoided.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Imageamento Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...